Suitable for performing Kesternich test with addition of SO2 (Sulphur Dioxide) gas and in ambient atmosphere. Also available without SO2 gas unit option. The test chamber has an internal capacity of 300L and it is built completely in plastic material.
Completely automatic execution of cycle. Phase with gas saturated atmosphere: loading of water dosage and SO2 gas every 8 hours at 40°C, unloading of chamber. Ambient phase: 16 hours of chamber ventilation with compressed air. The cycle is repeated constantly. Supplied with 4 bars specimen and 2 panel rack holders. Shipped completely wired and assembled.
In accordance with following norms:
ASTM D1735, ASTM D2247, BS 3900/F9, DIN 50017, DIN 55958, DIN 55991, ISO 11503, ISO 6270, ISO 4541, ISO3231, NFT 30-077, DIN 50017-KFW, DIN 50017, EN ISO 6988 DIN 50018, DIN 53771, NFT 30-055, SFW 2,0 S, VDA 621-421, VCS 1027.
DAMP HEAT CHAMBER MODEL | D200 |
Dimensions | (W x D x H) |
External mm. | 940x540x1370 |
Internal (without cover) mm. | 740x520x700 |
Volume (without cover) litres | 300L |
Weight Kg. | 90 |
Electrical supply |
|
Type of connection | 1/N/PE |
Voltage | 230 Vac +/-10% 50-60 Hz |
Current consumption (max) | 4 A |
Water supply |
|
Type of water | Demineralised |
Water pressure (BAR) | 2 |
Water consumption (indicative) (litres/day) | 2-4 |
Air supply |
|
Type of air | Filtred / oil free |
Air pressure (BAR) | 2 |
Air consumption (indicative) (Nm3/h) | 6 |
Temperature range |
|
Test chamber temperature range | Ambient up to 55°C |
Supplied accessories |
|
Rods | 4 |
Test panel racks | 2 |
Air filter and pipe (4 m) | YES |
Water filter and pipe (4 m) | YES |
GAS supply |
|
Type of GAS | SO2 |
GAS pressure (BAR) | 0,2 |
GAS consumption (indicative) (litres/day) | 0,2 -2 |