CORROSIONBOX-H | hust.com.vn | COFOMEGRA-ITALIA

CORROSIONBOX-H

lien_he

CORROSIONBOX-H

Model: 600L/1000L/2000L (Basic or enhanced)

Maker: Cofomegra - Italia

Horizontal test chambers with clear cover for salt spray, condensation tests and cyclic corrosion tests.

Available in 5 models: from 600 to 2000 litres. Special dimensions available on request

CORROSIONBOX-H

Model: 600L/1000L/2000L (Basic or enhanced)

Maker: Cofomegra - Italia

Corrosionbox improves comparison with outdoor results

Worldwide, materials used by manufacturing industry are exposed to natural or industrial corrosion in shape of salt fog, humidity, smoke and vehicle exhaust. Laboratory corrosion tests are used extensively for selection of materials and their surface protection.

Corrosionbox chambers are what you need to predict corrosion resistance of materials such as paints and coatings.

National and international Standards

In order to generate reliable and comparable results, a large number of test methods and international standards have been developed and are relied upon as reference for test execution.

Most popular tests:

 

 

   Basic models

         Enhanced models

50180 method A1/A2/A3

AS 2331 method 3 ASTM B117 ASTM B287 ASTM B368 ASTM D1735 ASTM D2247 ASTM G85 A1

BS 3900/F12 BS 3900/F4 BS 3900/F9

BS 5466 Part 1/2/3

BS 7479

BS EN 60068-2-11 BS EN ISO 7253 BS 2011 Part 2.1

D17 1058

DEF 1053 METH 24

EF 1053 METH 36

DIN 40046

DIN 50 017-KK

DIN 50021

DIN 50907

DIN 50958

DIN 53167

DIN 55991 ECCA T8

FLTM BI 103-01 GM4298P GM4465P

IEC 60068-2-11

JIS H 8502

Meth1/2/3 JIS Z 2371

JNS 30.16.03

ISO 11503

ISO 1456

ISO 3768

ISO 3769

ISO 3770

ISO 4541

ISO 6270

ISO 7253

ISO 9227 MIL-STD-202 NFT 30-077

NFX 41-002 RES.30.CT.117 SIS 184 190

VG 95 210

ASTM G43 ASTM G85 A3

DEF 1053 METH 36 RES.30.CT.119 DIN 50907

DRY MIL-STD-810 UNI 9399

UNI 9590

UNICHIM 652

UNICHIM 741

PROHESION

ASTM G85 /A5

 

Salt spray test

A corrosive solution is turned into a vapour mist through a nozzle located in the centre of the chamber. A fog diffusing tower distributes the fog over the entire test zone. The compressed air required for fog production is heated and saturated with moisture in a pressurized humidifier before it reaches the nozzle.

One or more heating elements, depending on chamber capacity, ensure uniform temperature in the test chamber. Exhaust solution collected in the bottom of test chamber is drained away through a drain to the floor.

Salt spray test can be executed with all chamber models.

Condensation water test

Test chamber bottom is filled with demineralised water. Water is heated and evaporates condensing on the surface of samples. Chamber temperature is 40°C.

Continuous condensation test can be executed with all chamber models.

 

Cyclic corrosion test

A large number of cyclic corrosion tests are made possible by combining salt spray environment with condensation humidity and air drying. Cyclic corrosion testing has become increasingly necessary in recent years. Dry Corrosion is one of the most popular cyclic tests alternating salt spray and air drying.

Cyclic tests can be executed with all enhanced model chambers. Depending on cycle-type some options have to be installed during chamber manufacturing.

 

Chamber Design

 

  

Chamber structure is overall 10mm thick Polypropylene. Option in PPS plastics to meet CSA flam test. Test chamber is insulated with a double wall. Access to the test chamber is made via the pivoting transparent cover for models 600/1000 litres (optional on model 2000 litres). Control panel and all necessary control devices are on the right side in ergonomic position. The Salt solution storage tank is on the left side. The electrical board is completely enclosed in a dedicated zone: next to it we find the electro-valves, humidifier and salt solution dosing pump zone. Each part is of easy access for simple and fast maintenance.

 

    Basic model

 

Absolutely easy to use. The first step for test execution is to load timer with total test time (up to 9999 hours), second is to set test chamber temperature on the controller, then press Salt spray or Condensation push-button. During the whole time of the test, the timer counts down and its display will indicate decreasing time running to test end. To inspect samples, suspend test execution pressing Salt spray or Condensation push-button, then press ventilation push-button to drain test chamber before opening it.

To resume test execution simply press Salt spray or Condensation push-button again. When timer reaches zero test execution is finished.

Enhanced model

 

Free programming, up to 15 different test programs, inputs via keyboard with soft keys and easy to use structure of the Menu. Test status is continuously displayed on the large LCD display with 4 lines of 20 characters each. Control and monitoring of test chamber and humidifier temperature, monitoring of nozzle air pressure and dosing pump RPH. Self-diagnostic including warning messages, alarm messages and safety shut down. Complete test report: chamber and humidifier temperature, nozzle air pressure and dosing pump RPH are periodically measured and stored in the controller memory together with test interruptions or alarms. By simply pressing a key a complete report of the test is printed. RS232-C interface is provided for serial printer connection.

Cyclic test options

Enhanced model control panel allows easy programming of cyclic test combining: Salt spray, Water condensation, Dry off and Ambient condition. To perform cycling the test chamber must be completed with the following optional parts:

Option for Dry Corrosion, Scab Corrosion cycle. An air heater is installed to heat purging air before introducing it in the test chamber and a Titanium panel on the bottom of test chamber turns a flooded bottom into a dry bottom. Only a dry chamber bottom allows fast drying of the samples.

Option for ASTM G85-98 annex 5 Prohesion. In addition to parts installed for dry corrosion a bypass is installed on the humidifier to meet standard requirements with respect to fog production.

Option for ASTM G85-98 annex 4 salt/SO2 spray testing. An external SO2 dosing system is supplied and a gas diffusing device is installed in the test chamber.

 

                                         Features / Models

basic

enhanced

Strong structure overall 10mm thick polypropylene construction with built-in salt solution reservoir.

yes

yes

Access to test chamber with pivoting cover with water seal.

yes

yes

Complete Spray nozzle made in plastic material, suitable for ISO 9227 AASS and CASS tests.

yes

yes

Fog diffuser in the centre of the test chamber allows fog uniformity.

yes

yes

Complete rain gauge (fog collector).

yes

yes

Rain gauges system with readings located outside of chamber.

yes

yes

Humidifying tower with automatic water level restoring system and temperature-controlled water heater.

yes

yes

Peristaltic pump for salt solution dosage.

yes

yes

Ergonomic control panel.

yes

yes

Pressure regulator for control of nozzle air pressure.

yes

yes

Pressure gauge for display of nozzle air pressure.

yes

no

Digital temperature controller of test chamber temperature.

yes

no

Instrument for temperature calibration.

yes

yes

Timer to set test duration, programmable up to 9999 hours, with stopping of all functions at test end.

yes

no

Pilot lamp to signal lack of salt solution.

yes

no

Microprocessor control panel. Test status continuously displayed on a large LCD with 4 lines display for test parameters and program menu.

no

yes

Free programming, up to 15 different test programs, input via keyboard with soft keys and tactile feedback.

no

yes

Self-diagnostic, routine service reminders including warning messages and safety shut down.

no

yes

Complete test report: chamber test temperature, humidifier temperature, air nozzle pressure, dosing pump RPH are periodically measured and saved in the controller memory, and by simply pressing a key you can print a complete report of the test.

 

no

 

yes

Data transfer via RS232-C serial interface.

no

yes

Air and water filter to be installed on supply lines.

yes

yes

Rod bars and standard specimen holders supplied.

yes

yes

 

Technical data / Models

600l basic / enhanced

1000l basic / enhanced

2000l enhanced

Physical dimensions 

Overall dimensions  (mm)

2010 x 910 x 1400 (WxDxH)

2400 x 1180 x 1365 (WxDxH)

3000 x 1200 x 1480 (WxDxH)

Test chamber internal dimensions (without dome area) (mm)

1300 x 650 x 700 (WxDxH)

1690 x 890 x 700 (WxDxH)

2890 x 980 x 700 (WxDxH)

Test chamber volume (without dome area)  (litres)

600

1050

2000

Weight  (Kg)

300

400

550

Salt solution reservoir capacity (litres)

130

160

450 (external module)

Electrical supply

 

 

 

Type of connection

 

1/N/PE

 

Voltage (V)

 

230 +- 10 % 50 Hz

 

Current consumption (A)

9

12

18

Water supply for humidifier

 

 

 

Type of water

 

demineralised

 

Water pressure  (bar)

 

2-4

 

Water consumption (approximate) (litres/day)

 

3

 

Air supply

 

 

 

Type of air

 

Filtered, oil free

 

Air pressure (bar)

 

4-6

5-6

Air consumption (approximate) (Nm3/h)

 

5-8

12

Temperature range

 

 

 

Test chamber temperature range (°C)

 

Ambient to 55

 

Humidifier temperature range (°C)

 

Ambient to 70

 

Supplied accessories

 

 

 

Rod bars

4

6

8

Test panel racks specimen holder

3

4

4

Air filter and pipe (4 m)

yes

yes

yes

Water filter and pipe (4 m)

yes

yes

yes

 

 

Bình luận

Salt water spray tester VISIONTEC

lien_he

Features:

Spraying of uniform particle mist inside Chamber available by using the Specialy Nozzle.

Comply with the Salt Water Spray Tester VT-ST 100/200/300

NSS Test (35oC ± 2oC) & CASS Test (50oC ± 2oC) requirements.

Possible Cycle operation, Power-saving type.

Test Standards:  KS D9502 , JIS Z 2371 , ASTM B 117 , DIN50 021

Salt water spray tester VT-ST 400-86/480-86

lien_he

 Features:

Spraying of uniform particle mist inside Chamber available by using the Specialy Nozzle.

Comply with the Salt Water Spray Tester VT-ST 400-86/480-86

NSS Test (35oC ± 2oC) & CASS Test (50oC ± 2oC) requirements.

Possible Cycle operation, Power-saving type.

Test Standards:  KS D9502 , JIS Z 2371 , ASTM B 117 , DIN50 021

Cyclic corrosion test (CCT)

lien_he

Cyclic Corrosion Tester

Easy to set up temperature raising, maintenance and cooling by using programmable Temperature Controller.

Easy keeping data record by using recorder.

CORROSIONBOX

lien_he

CORROSIONBOX

Available in 4 models: 400 and 1000 litres, basic and enhanced.

Maker: Cofomegra - Italia

DAMP HEAT CHAMBER AUTOMATIC with SO2 - 300L (D200)

lien_he

Damp heat chamber AUTOMATIC for high humidity tests in Constant (CH) and Alternate (AHT, AT) atmosphere to simulates rain and dew by condensing liquid water directly onto the test specimen (high humidity 95% to 100% saturated atmosphere).

Model: D200

Maker: COFOMEGRA - Italia