RoHS 1.0 standard regulates the control of toxic substances in electrical and electronic products,... such as: Cd, Pb, Hg, Cr6+, PBB and PBDE.
To meet RoHS 1.0 standard, the suitable solution is X-ray fluorescence spectrometer (XRF).
For RoHS 2.0 standard, 4 additional Phthalates compounds need to be controlled: DIBP, DBP, BBP, DEHP. And to quantitatively analyze these 4 compounds, the suitable method is to use Gas Chromatography.
A traditional gas chromatography mass spectrometry device is often very complex and expensive, while TP30 PRO is a solution that completely meets customer requirements, but has many advantages such as:
No chemical pretreatment: no ultrasonic extraction, no chemical reagent extraction, direct solid or liquid injection, simple operation.
Short sampling time: 20 minutes / sample sampling time to fully meet the needs of corporate users rapid testing;
No need for EIA, no need for professional laboratory: no reagents, no pre-treatment, no waste gas or liquid, no need to apply for EIA;
100% sample applicability: the chemical method is only applicable to soluble polymer samples (70% of samples applicable), this method is applicable to soluble, insoluble and insoluble polymer samples (100% of samples applicable);
No specialized laboratory environment is required: only an ordinary operating space with air conditioning, power supply and operating table is required for installation and use.
Technical parameters:
Temperature range of cracking unit (Φ6 cracking tube): room temperature to 450°C, in 1°C increments.
Cracking device (Φ6 cracking tube) temperature increase rate: >500℃/min.
Cracking time range of the cracking device: 0.01-99.99 min, set in increments of 0.01 min.
Cracker purge time range: 0.01 to 99.99 min in 0.01 min increments.
Cracker purge flow rate range: 10 ml to 200 ml.
Cracking device diversion flow rate range: 10 ml to 200 ml.
Cracking device heating control voltage: 16VDC.
Temperature range of aging and cleaning device: room temperature to 450°C, set in increments of 1°C (optional).
Aging and cleaning device time range: 1 to 1200 min, set in increments of 1 min.
Column temperature box system:
Temperature range: ambient temperature +5℃~450℃.
Three-step program heating, heating rate 0 ~ 50 ℃ / min; increment 0.1 ℃ / min. temperature control accuracy ± 0.015 ℃.
The user can recalibrate the furnace temperature and set the maximum temperature at will. Intelligent rear door opening system stepless variable inlet and outlet air volume, shorten the heating/cooling system stabilization and equilibrium time.
The system stabilizes the equilibrium time after the temperature rise/fall. The time taken to reduce the temperature of the column box from 300℃ to 50℃ is less than 12min.
Detector system:
Hydrogen flame ionization detector (FID):
Easy to disassemble and install, easy to clean or replace the nozzle, simple operation; input signal can be logarithmically amplified, reducing interference, high sensitivity, good linearity, wide range.
Detection limit: Mt ≤ 5 × 10-12 g / s (n-hexadecane) Baseline noise: ≤ 6 × 10-12 A/H
Linear range: ≥105
Stabilization time: < 0.5h